$ run IPv4 Calculator
NetCalc by Alexmysterio — Mobile app coming soon · Telegram bot available

Enter runs the calculation · Shift+Enter inserts a new line

user@netcalc ~/calc $

ipv4_calculator

Calculate network, broadcast, mask, hosts, class and binary for any IPv4 address

ip:
mask:
user@netcalc ~/calc $

ipv6_calculator

Calculate network info for IPv6 addresses in CIDR notation

ipv6:
pfx:
user@netcalc ~/calc $

vlsm_calculator

Variable Length Subnet Mask — assigns optimal blocks for each network segment

net:
pfx:
// Subnets required
name:
hosts:
name:
hosts:
name:
hosts:
user@netcalc ~/calc $

usable_ip_range

Shows the exact usable host range for a given network

ip:
mask:
user@netcalc ~/calc $

binary_ip_calc

Convert IP addresses to binary and vice versa, with per-octet visualization

dec:
bin:
user@netcalc ~/network $

cidr_converter

Convert between CIDR, decimal mask and wildcard. Includes full /1–/32 reference table.

in:
📋 CIDR Reference Table
CIDRSubnet MaskWildcardHosts/24 subnetsBlock
user@netcalc ~/network $

wildcard_mask_calc

Calculate the wildcard (inverse) mask for Cisco ACLs, OSPF and firewall rules

mask:
user@netcalc ~/network $

supernet_calculator

Find the minimum supernet containing all specified networks (route summarization)

nets:
user@netcalc ~/network $

subnet_splitter

Split a network into equal subnets by specifying a new prefix

net:
mask:
new:
user@netcalc ~/network $

range_to_cidr

Convert an IP range (start–end) to the minimum set of CIDR blocks

start:
end:
user@netcalc ~/network $

ip_to_integer

Convert IPv4/IPv6 addresses to integer and vice versa

ip:
int:
user@netcalc ~/network $

ipv6_normalize

Expand and compress IPv6 addresses — normalize any valid format

ipv6:
user@netcalc ~/network $

hex_ip_converter

Convert between hexadecimal and IP address — useful for Windows route tables and Cisco logs

ip:
0x:
user@netcalc ~/network $

vlan_calculator

802.1Q VLAN info: tag encoding, PCP, DEI, VID, range and compatibility

vlan:
pcp:
dei:
user@netcalc ~/dns $

reverse_dns_generator

Generate the PTR in-addr.arpa zone for an IPv4 network

net:
pfx:
dom:
user@netcalc ~/dns $

ipv6_ptr_generator

Generate the PTR ip6.arpa record for an IPv6 address

ipv6:
host:
user@netcalc ~/dns $

ip_geolocation

Locate a public IP or resolve a domain and geolocate its public address

Domains are resolved through DNS first; geolocation is based on the resulting public IP.
geo:
user@netcalc ~/dns $

ip_address_planner

Interactive IP address space planner — click cells to edit, export to CSV

📋 IP Address Plan
#NameNetworkMask/CIDRGatewayVLANLocationNotes
user@netcalc ~/legal $

Privacy

Data stored in your browser

Theme, language, promotion dismissal and calculation history are stored in localStorage on this device.

Calculations

Calculations are sent through this site's same-origin Worker proxy to the private calculation service.

Performance metrics

LCP, CLS and INP may be stored as aggregate performance measurements by tool and language. Calculation inputs and persistent user identifiers are not included.

GeoIP

Only GeoIP lookups are processed by an external provider. The requested IP address is sent for that lookup.

Issue reports via Telegram

A report link opens the public Telegram bot and includes only the current page slug in the bot start parameter. Calculator inputs and report text are not sent by this website. Text you choose to send inside Telegram is handled by Telegram and the bot.

Cookies and advertising

Advertising is controlled by the production configuration. When Google AdSense is enabled, consent is handled through a certified CMP before personalized advertising is used where required.

Delete local data

Use the button below to clear calculation history. To remove every local preference, clear this site's data in your browser settings.

This page provides operational information; it is not a legal-compliance certification.

Diagnóstico de trunks VLAN: tagged, untagged y errores de VLAN nativa

Sigue la pertenencia VLAN extremo a extremo e identifica desajustes de PVID, VLAN nativa y listas permitidas que provocan conectividad parcial o intermitente.

Por 2026-09-21≈ 6 min7 apartados
EthernetMTU 1500 PPPoE1492 bytes Túnel≈ 1420 TCP MSSpayload seguro Regla de diseñounderlay − encapsulación = MTU interior; después valida el camino real
Cómo se reduce la MTU a través de una pila de encapsulación
01

Sigue una VLAN de extremo a extremo

Empieza por el puerto de acceso y continúa por cada trunk, bridge e interfaz virtual. Anota si cada salto espera la VLAN tagged o untagged. Un único desacuerdo puede aislar un servicio mientras otros siguen funcionando.

02

PVID y VLAN nativa clasifican entrada, no hacen magia

Una trama sin tag que entra por un puerto se asigna a una VLAN según sus reglas de ingreso. Esa misma VLAN puede salir por otro puerto con tag o sin él. Trata clasificación de entrada y etiquetado de salida como decisiones separadas.

03

Las listas allowed producen fallos parciales

Un trunk puede transportar gestión y voz correctamente y descartar una nueva VLAN de clientes porque falta en una lista permitida de un lado. Compara ambos extremos e intermedios aunque parte del trunk funcione.

04

Evita depender de VLAN nativa mal alineada

Los fabricantes nombran native, PVID, untagged e hybrid de forma distinta. Construye una matriz explícita de tagging por enlace y verifícala con aprendizaje MAC o captura en lugar de traducir comandos solo por nombre.

05

Usa aprendizaje MAC como tracer de capa 2

Una MAC origen debe aparecer en la VLAN esperada en cada switch del camino. Si desaparece o cambia de VLAN en un salto, has localizado el desajuste de tagging o PVID.

06

Recuerda que gestión y clientes pueden usar VLAN distintas

Poder gestionar ambos switches solo demuestra alcance IP en la VLAN de gestión. No demuestra que la VLAN de cliente esté presente en la allow-list del trunk.

07

Documenta trunks como una matriz

Para cada enlace anota VLAN permitidas y si cada una sale tagged o untagged. Esta descripción neutral traduce mejor entre MikroTik, Cisco, Huawei y smart switches que los nombres específicos del fabricante.

EX

Ejemplo trabajado

  1. Host A entra untagged en VLAN 40 en Switch 1.
  2. El uplink debe transportar VLAN 40 con la misma expectativa de tag en ambos switches.
  3. Switch 2 entrega VLAN 40 untagged al puerto de destino.
  4. Si la MAC desaparece en el trunk, compara VLAN allowed y PVID/native en ambos extremos.
✓

Checklist operativo

  • Escribe la matriz VLAN/tagging de cada trunk.
  • Compara listas allowed en ambos extremos.
  • Verifica PVID/VLAN nativa para entrada untagged.
  • Usa MAC learning o captura para demostrar el salto que falla.

Estándares y referencias